Capsule Gauges for Low Pressure Models KPChE 63,
KPChg, and KPCh |
Download:* |
Model |
KPChE |
Capsule gauges for
low pressure model KPChE are for applications (low pressure measurement) where a small
stainless steel case is required. |
|
|
These gauges suit
for air pressure measurement or for other gaseous media which are compatible to the wetted
parts. |

|
Capsule gauges are
used e.g. from domestic gas supply companies and gas regulators, boiler or furnace
manufacturers etc. |
Nom. Case Size: |
63 (2½") |
| Case: |
304 stainless steel |
| Lens: |
acrylic glass,
snapped-in into the case |
Pressure Ranges: |
0-2.5 mbar - 0-600 mbar or
0-1"WC (inch water) - 0-250"WC
(also vacuum or compound ranges) |
| Accuracy: |
1.6 % f.s. |
|
Process Connection: |
¼" BSP, ¼" NPT or M 12 x 1,5
bottom or center back connection |
|
Wetted
Parts: |
brass /
copper-beryllium or
stainless steel |
|
Details and Special
Configuration: |
see data sheet 6211.1 |
|
Data
Sheets:
German
6211-1.pdf
English
6211-1-eng.pdf
|
Model |
KPChg |
The
stainless steel case of our model KPChg is provided with a crimped-on ring and acrylic glass
lens. This version is available in nom. case sizes 80 (3")
and 50 (2"). |
| Capsule gauges suit
for air pressure measurement or for other gaseous media which are compatible to the wetted
parts. They are used e.g. from domestic gas supply companies and gas regulators, boiler or
furnace manufacturers etc. |

|
Nominal Case Sizes: |
50 mm (2")
80 mm (3")
|
| Case: |
304 stainless steel |
| Ring: |
crimped-on ring 304
stainless steel |
Pressure Ranges: |
NCS 50 =
0-160 mbar - 0-600 mbar
0-60"WC (inch water) - 0-250"WC
NCS 80 =
0-2,5 mbar - 0-600 mbar
0-1"WC (inch water) - 0-250"WC
(also vacuum or compound ranges) |
| Accuracy: |
1.6 % f.s. |
|
Process Connection: |
NCS 50:
¼" BSP, ¼" NPT or M 12x1,5
bottom or center back connection
NCS 80:
½" BSP, ½" NPT or M 20 x 1,5
bottom or center back connection |
|
Wetted Parts: |
NCS 50:
brass / copper-beryllium
NCS 80 :
brass / copper-beryllium or
stainless steel
|
|
Details and Special
Configuration: |
see data sheet 6203 |
|
Data Sheets:
German
6203.pdf
English
6203-eng.pdf
|
Model |
KPCh |
Capsule gauges for low pressure
model KPCh are for applications (low pressure measurement) where a sealed case with
chemical resistance is required. |
|
|
These gauges suit for air pressure
measurement or for other gaseous media which are compatible to the wetted parts. |

|
Capsule gauges are used e.g. from
domestic gas supply companies and gas regulators, boiler or furnace manufacturers etc. |
Nom.
Case Sizes: |
100 mm (4")
160 mm (6") |
| Case: |
304 stainless steel |
| Ring: |
bayonet ring 304
stainless steel |
Pressure Ranges: |
0-2.5 mbar - 0-600 mbar or
0-1"WC (inch water) - 0-250"WC
(also vacuum or compound ranges) |
| Accuracy: |
1.6 % f.s. |
|
Particularities: |
zero adjustment |
|
Process Connection: |
½" BSP, ½" NPT or M 20 x 1,5
bottom or center back connection |
|
Wetted
Parts: |
brass /
copper-beryllium or
stainless steel |
|
Details and Special
Configuration: |
see data sheet 6201 |
|
Data
Sheets:
German
6201.pdf
English
6201-eng.pdf
|