Limit switch contact assemblies for pressure gauges and thermometers (data sheet 9.1000)
model |
I (inductive contact) |
application / operating conditions |
Inductive contacts in connection with our multifunctional relays models MSR-I are suitable for every industrial application.- they are wear resistant (contactless switching) and corrosion-free (all electrical parts are water resistant moulded in a plastic case in cast resin).
- proximity switches are applicable according to IEC 61 508 up to SIL 2.
|
installation in case-Ø |
63, 100, 160, 96x96 and 144x144 |
case filling |
Limit switch contact assemblies with inductive contacts can be applied in instruments with case filling. |
Ex-protection |
For the use of our switch amplifiers KF..-SR2-.. the equipment corresponds to the protection type intrinsic safety i. It belongs to classification II2G EExia IIC T6 and is approved for the application in potentially explosive areas. |
Certificates
Data sheet download